SL62 · SL72 · SL82 · SL92 · SL102
Square reinforcing mesh commonly formed from Grade 500L ribbed wires. Australian SL sheets can incorporate smaller edge side-lapping wires as specified by the standard mesh configuration.
View AU square mesh sizes ↗Welded reinforcing steel mesh for Australian and New Zealand projects. Request square SL mesh, rectangular RL mesh or New Zealand SE structural mesh by grade, sheet designation, dimensions and project quantity.
AS/NZS 4671 describes factory-made resistance-welded reinforcing mesh with defined wire grades, joint performance and geometric tolerances. Australian and New Zealand catalogues use different standard sheet designations and ductility requirements.
Square reinforcing mesh commonly formed from Grade 500L ribbed wires. Australian SL sheets can incorporate smaller edge side-lapping wires as specified by the standard mesh configuration.
View AU square mesh sizes ↗Rectangular mesh uses closer-spaced main bars and a different cross-bar layout. Procurement drawings should specify the direction of principal reinforcement.
View AU rectangular mesh sizes ↗New Zealand structural welded mesh is specified with Grade 500E seismic ductility. The standard distinguishes these SE products from non-structural 500L mesh.
View NZ structural mesh sizes ↗Buy to the mesh designation, steel grade and manufacturing details stated on the project schedule. Our quotation review matches the required pitch, wire profile, sheet dimension, edge arrangement and test documents to the proposed production lot.
The AS/NZS 4671 standard includes distinct tables for Australia and New Zealand. The following standard reference sheet masses are based on 6.0 × 2.4 m panels; actual supply details are confirmed against the order and production records.
| Mesh | Longitudinal bar | Cross bar | Arrangement | Mass / sheet |
|---|---|---|---|---|
| SL62 | 6.0 mm @ 200 mm | 6.0 mm @ 200 mm | Square; edge side-lapping bars | 33 kg |
| SL72 | 6.75 mm @ 200 mm | 6.75 mm @ 200 mm | Square; edge side-lapping bars | 41 kg |
| SL82 | 7.6 mm @ 200 mm | 7.6 mm @ 200 mm | Square; edge side-lapping bars | 52 kg |
| SL92 | 8.6 mm @ 200 mm | 8.6 mm @ 200 mm | Square; edge side-lapping bars | 66 kg |
| SL102 | 9.5 mm @ 200 mm | 9.5 mm @ 200 mm | Square; edge side-lapping bars | 80 kg |
| RL818 | 7.6 mm @ 100 mm | 7.6 mm @ 200 mm | Rectangular | 79 kg |
| RL1018 | 9.5 mm @ 100 mm | 7.6 mm @ 200 mm | Rectangular | 109 kg |
| RL1218 | 11.9 mm @ 100 mm | 7.6 mm @ 200 mm | Rectangular | 157 kg |
For Australian SL mesh, the edge side-lapping wire configuration affects the full-sheet weight. The simple two-direction diameter/pitch approximation is not a replacement for the specified wire count and edge arrangement.
| Mesh | Grade | Nominal wires | Pitch | Mass / sheet |
|---|---|---|---|---|
| SE62 | 500E | 6.1 mm longitudinal / 6.0 mm cross | 200 × 200 mm | 33 kg |
| SE72 | 500E | 7.0 mm each way | 200 × 200 mm | 45 kg |
| SE82 | 500E | 8.0 mm each way | 200 × 200 mm | 59 kg |
| SE92 | 500E | 9.0 mm each way | 200 × 200 mm | 75 kg |
| SL41.5 | 500L | 4.0 mm each way | 150 × 150 mm | 19 kg |
| SL51.5 | 500L | 5.3 mm each way | 150 × 150 mm | 32 kg |
SE62 uses the specified wire sizes for each direction under the standard's New Zealand table. For SE and SL designation matching, inspect the actual number of wires, edge overhang and production drawing in addition to nominal mesh pitch.
Send your product code, required sheet quantity and any project inspection or certification conditions.
Select a standard designation for its published reference sheet mass, or calculate a purpose-made panel from its actual longitudinal and cross-wire counts. Results help estimate material tonnage before quotation.
Reference mass for standard designations · Geometric estimate for custom sheets
Longitudinal wires run the full sheet length; cross wires run the full width. Include additional edge wires in the actual counts. Calculations use nominal circular sections and 7,850 kg/m³ density.
Published sheet masses are catalogue reference values. Custom estimates exclude weld additions, actual tolerances, protective packaging and transport dunnage. Final shipment mass is confirmed by order.
Steel ductility class is a material and project acceptance requirement. Standard Australian SL/RL mesh is commonly produced from 500L reinforcement; New Zealand SE structural mesh requires 500E mechanical properties.
| Characteristic property | 500L · Low ductility | 500E · Earthquake ductility |
|---|---|---|
| Lower characteristic yield stress | ≥ 500 MPa | ≥ 500 MPa |
| Upper characteristic yield stress | ≤ 750 MPa | ≤ 600 MPa |
| Characteristic tensile/yield ratio, Rm/Re | ≥ 1.03 | ≥ 1.15, upper ≤ 1.40 |
| Characteristic elongation at maximum force, Agt | ≥ 1.5% | ≥ 10.0% |
| Maximum carbon equivalent, cast analysis | 0.39% | 0.49% |
| Maximum carbon equivalent, product analysis | 0.41% | 0.51% |
Values are characteristic requirements in AS/NZS 4671:2019 Tables 7.1(A) and 7.2(A). A special provision applies to certain 500L products below 5 mm; actual sampling, test-piece condition and conformity must follow the standard. Project specifications determine the grade and mesh designation.
500L low-ductility sheets and 500E structural mesh have different acceptance criteria. Production-lot test records, specified conformity reports and any independently required product certification are reviewed against the actual manufacturing site.
Longitudinal wires are aligned and fed beneath transverse wire positioning equipment. The mesh welding head forms resistance-welded intersections, followed by panel cutting, stacking and lot identification.
See our mesh welding production line and reinforcing mesh sheets range for more on available manufacturing formats.
AS/NZS 4671:2019 specifies joint-shear performance and dimensions for machine-welded mesh. Material testing, grade identification and manufacturing-lot traceability support the project's product acceptance programme.
For applicable joint tests, the welded intersection must withstand a direct shear force of at least 0.5 × specified yield grade × nominal cross-sectional area of the largest wire at the joint.
Mesh where the wire size difference is at least 3 mm is excluded from this particular joint-shear test requirement. The relevant test method and sampling procedure are followed for each production type.
Quality checks compare main and cross-wire pitch, mesh width and length, edge overhang and finished product identification with the approved schedule. Relevant mill records and the test certificate identify the actual grade and manufacturing lot.
Any project requirement for ACRS or another accredited third-party certification needs to be supported by a valid certificate covering the applicable manufacturer and product scope.
Explore Quality Control ↗Mesh designation and reinforcement grade are selected from the structural design, slab schedule and specified local acceptance pathway.
Australian SL mesh and project-specified reinforcement for concrete slabs, industrial hardstands and related flat concrete elements.
Rectangular RL mesh or custom bar arrangements based on the required principal reinforcement direction and engineering schedules.
Grade 500E structural mesh where required by applicable New Zealand concrete design and building documentation.
Material grade, position, cover, lap length, mesh orientation and installation requirements are determined by the design. Supply quotations focus on the specified mesh designation and documented steel properties.
Finished mesh sheets are stacked on stable, evenly spaced supports, kept flat, secured for loading and labelled by specification and lot. The shipping plan accounts for panel geometry, bundle mass, handling equipment and receiving-port requirements.
Company-wide steel stock supports project supply programmes; quantities of any specific AS/NZS mesh designation are confirmed against available production and shipping schedules.
Include the manufacturing standard, required designation, number of sheets, destination and inspection requirements.
SL generally refers to the Australian square mesh family, while RL designates rectangular layouts with a different main and cross-wire arrangement. Purchase schedules should include the complete mesh code and reinforcement orientation.
Grade 500L and 500E have different tensile ratio and elongation requirements. 500E is the earthquake ductility class used for New Zealand structural mesh where specified by the project.
Australian SL configurations can include smaller side-lapping edge wires, and the full sheet includes specific numbers and lengths of wires. Reference sheet masses incorporate the standard layout, while custom theoretical estimates use the actual wire counts.
Specify grade, mesh designation, heat and mesh-lot identification, dimensional and mechanical test results, relevant weld shear reports, and any project-mandated third-party product certification covering the actual supplier and product.
Send your Australian SL/RL or New Zealand SE reinforcing mesh schedule. Include the standard, wire grade, sheet designation, quantity, delivery destination and any project acceptance documents.
Standard MOQ: 25 MT. Scheduled 500 MT and larger programmes are welcome.
Attach the reinforcement schedule or drawing for an accurate quotation.
Include the mesh code, sheet quantity and destination.
Complete your requirements and send them to our team.
Automated page speed optimizations for fast site performance